=========================================================================== ZMCIRT Vulnerability Bulletin ZMC-2021.12.2.0800 Distributed Data Systems WebHMI: Multiple vulnerabilities 2nd December 2021 =========================================================================== Product: Distributed Data Systems WebHMI Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Administrator Compromise -- Remote/Unauthenticated Execute Arbitrary Code/Commands -- Remote/Unauthenticated Unauthorised Access -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2021-43936 CVE-2021-43931 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-21-336-03 - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-21-336-03) Distributed Data Systems WebHMI Original release date: December 02, 2021 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 10.0 o ATTENTION: Exploitable remotely/low attack complexity o Vendor: Distributed Data Systems o Equipment: WebHMI o Vulnerabilities: Authentication Bypass by Primary Weakness, Unrestricted Upload of File with Dangerous Type 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an administrator account login without password authentication and remote code execution with root privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of WebHMI, a SCADA system with built-in web server capability, are affected: o All versions prior to 4.1 3.2 VULNERABILITY OVERVIEW 3.2.1 AUTHENTICATION BYPASS BY PRIMARY WEAKNESS CWE-305 The authentication algorithm is sound, but the implemented mechanism can be bypassed as the result of a separate weakness primary to the authentication error. CVE-2021-43931 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:H/I:H/A:H ). 3.2.2 UNRESTRICTED UPLOAD OF FILE WITH DANGEROUS TYPE CWE-434 The software allows the attacker to upload or transfer files of dangerous types that can be automatically processed within the product's environment or lead to arbitrary code execution. CVE-2021-43936 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:C/ C:H/I:H/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing o COUNTRIES/AREAS DEPLOYED: Germany, Poland, Ukraine, United States o COMPANY HEADQUARTERS LOCATION: Ukraine 3.4 RESEARCHER Marcin Dudek of CERT.PL reported these vulnerabilities to CISA. 4. MITIGATIONS Distributed Data Systems recommends: o Upgrading the platform software to the latest release, Version 4.1 CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls, and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target these vulnerabilities. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- ZMCIRT has made every effort to ensure that the information contained in this document is accurate. However, the decision to use the information described is the responsibility of each user or organisation. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. ZMCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. =========================================================================== Internet Email: report@cirt.zm Telephone: 7070 ZMCIRT personnel answer during Zambian business hours which are 8am to 5pm. On call after hours for member emergencies only. ===========================================================================
Copyright @2023 ZAMBIA CIRT