=========================================================================== ZMCIRT Vulnerability Bulletin ZMC-2021.10.15.0800 Siemens RUGGEDCOM ROX Devices: Denial of service - Remote/unauthenticated 15th October 2021 =========================================================================== Product: Siemens RUGGEDCOM ROX Devices Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Denial of Service -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2021-41546 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-21-287-08 - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-21-287-08) Siemens RUGGEDCOM ROX Devices Original release date: October 14, 2021 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 7.5 o ATTENTION: Exploitable remotely/low attack complexity o Vendor: Siemens o Equipment: RUGGEDCOM ROX o Vulnerability: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated attacker to cause a permanent denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of RUGGEDCOM ROX, switches and serial-to-Ethernet devices, are affected: o RUGGEDCOM ROX MX5000: All versions prior to v2.14.1 o RUGGEDCOM ROX RX1400: All versions prior to v2.14.1 o RUGGEDCOM ROX RX1500: All versions prior to v2.14.1 o RUGGEDCOM ROX RX1501: All versions prior to v2.14.1 o RUGGEDCOM ROX RX1510: All versions prior to v2.14.1 o RUGGEDCOM ROX RX1511: All versions prior to v2.14.1 o RUGGEDCOM ROX RX1512: All versions prior to v2.14.1 o RUGGEDCOM ROX RX1524: All versions prior to v2.14.1 o RUGGEDCOM ROX RX1536: All versions prior to v2.14.1 o RUGGEDCOM ROX RX5000: All versions prior to v2.14.1 3.2 VULNERABILITY OVERVIEW 3.2.1 UNCONTROLLED RESOURCE CONSUMPTION CWE-400 Affected devices write crash-dumps without checking if enough space is available on the file system. Once the crash-dump fills the entire root file system, affected devices fail to boot. An attacker can leverage this vulnerability to cause a permanent denial-of-service condition. CVE-2021-41546 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:N/I:N/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Germany 3.4 RESEARCHER Siemens reported this vulnerability to CISA. 4. MITIGATIONS Siemens has released updates for the affected products and recommends updating to the latest versions: o Update to v2.14.1 or later version . o Restrict access to the affected systems, especially to Port 443/TCP, to trusted IP addresses only. As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security , and to follow the recommendations in the product manuals. For additional information, please refer to Siemens Security Advisory. CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls, and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- ZMCIRT has made every effort to ensure that the information contained in this document is accurate. However, the decision to use the information described is the responsibility of each user or organisation. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. ZMCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. =========================================================================== Internet Email: report@cirt.zm Telephone: 7070 ZMCIRT personnel answer during Zambian business hours which are 8am to 5pm. On call after hours for member emergencies only. ===========================================================================
Copyright @2023 ZAMBIA CIRT